Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (2024)

Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (1)

Select the topic that fits your support needs:

  • Gather your supplies
  • Choosing insertion site
  • Top 5 CGM tips
  • Inserting the sensor with a buddy
  • Inserting the sensor yourself
  • Taping your sensor
  • Pairing your sensor
  • Starting your sensor
  • Sensor updating alert
  • Unpairing your transmitter
  • Disconnect your transmitter


Gather your supplies


Before you insert your sensor, gather all of your supplies:

  • One-press serteris required in order to insert the sensor properly.
  • Guardian™4 sensoris individually packaged and comes attached to a plastic pedestal which is necessary for proper loading into the serter.
  • Oval Tapeis required to keep the sensor securely in place.
  • TheGuardian™4 transmitteris connected after the sensor is inserted and is then covered with the Oval Tape.


Choosing insertion site


The Guardian™4 sensor is only approved to be worn in the back of the upper arm. There are two methods for inserting:

  • Inserting by yourself
  • Getting the help of a buddy to complete the insertion. This is often preferred by people who have trouble accessing the back of their arm easily.

Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (2)


Note: The Guardian™4 sensor is indicated for back of the upper arm use only. Do not use Guardian™4 sensor on the abdomen or other body sites including the buttocks, due to unknown or different performance that could result in hypoglycemia or hyperglycemia.

Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (3)


Other important factors to consider:

  • Sensor should be at least 1 inch away from your insulin pump infusion site
  • Sensor should be at least 1 inch away from any manual insulin injection site (syringe, pen)

For best sensor glucose performance, avoid these sites:

  • Where clothing may rub or constrict
  • Where your body naturally bends a great deal and may cause the sensor to pull out
  • Where you have scarred or hardened tissue or stretch marks
  • Where there is a great deal of motion or friction

To help provide the best experience when it comes to sensor life:​

  • Insert the Guardian™ 4 sensor in its approved insertion site (back of the upper arm).
  • After insertion, when removing the needle from the sensor, make sure to hold the base of the sensor firmly in place.​
  • During taping, use the two pieces of Oval Tape that come with your sensor. The first piece of Oval Tape covers the base of the sensor andholds it in place as you wear it, while the second piece helps keeps the transmitter secure. Additionalover tapecan also help keep yoursensor secure, especially if you’re active or live in a humid climate, so don’t be afraid to addextratape on top if you need it!​


Top 5 continuous glucose monitor (CGM) tips


How long your sensor lasts can depend on many factors, and we know things happen in day-to-day life! Here’s what you can do to help your Guardian™ 4 sensor last:

  1. Find your sweet spot: The Guardian™ 4 sensor is designed and approved to only be worn on the back of the upper arm which makes it the perfect spot for optimal sensor performance and longevity. So, make sure to stick with this location for the best experience! Don’t forget to choose a flat area on the back of your upper arm where you can “pinch an inch” that’s also free of scar tissue.
  2. Prep the skin: Before sensor insertion, it's important to prep your skin properly. Clean, dry skin is key. Some soaps have oils that can interfere with adhesive sticking, so give the area a quick wipe with an alcohol swab. And remember, let it dry completely before inserting the sensor!
  3. Get it to stick: After insertion, when removing the needle from the sensor, hold the base of the sensor firmly in place to prevent any movement that could impact performance. Don't forget about the two pieces of Oval Tape included with your sensor kit. One covers the base, and the other helps secure the transmitter. Feel free to add extra tape if you're extra active or live in a humid area.
  4. Do not worry if Sensor Updating appears! This is a safety feature that's most likely to happen on the first day. There's nothing you need to do unless your pump alerts you. Most of the time, it resolves on its own in an hour. But if it lasts for more than 3 hours, change the sensor and request a replacement.
  5. Use your resources: If you’re looking to dive deeper, you’ve come to the right place. Need a refresher on how to insert your sensor? Check out this step-by-step instructional video or this one-handed arm insertion video from our very own Ambassador, Rob Howe. Getting help from a friend? This video is the one for you. Need handy hints for making sure your sensor stays put? This Tape Tips Guide can help. The support page you’re on also has loads more info and assistance for all things related to your sensor; make sure to check it out.

Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (4)



Inserting the sensor with a buddy


Here are some helpful tips that can hep your sensor’s longevity and performance.

  1. Choose an insertion site on the back of your upper arm that’s free of scar tissue.
  1. Prep the skin using an alcohol wipe and let your arm completely dry before inserting.

    Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (5)

  1. After insertion, when your buddy helps you remove the needle housing, have them hold the base of the sensor firmly in place to prevent any movement.

    Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (6)


  1. Always use both pieces of Oval Tape as the product instructions direct. The first piece covers the base of the sensor (before you connect the transmitter) and holds it in place as you wear it, while the second piece helps keep the transmitter secure.

    Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (7)

  1. Additional tape on top of the Oval Tape can also help keep your sensor secure especially if you’re active or live in a humid area.

    Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (8)


Want to see the full insertion process?

Watch this video for tips on inserting your sensor on the back of your arm with the help of a buddy.

Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (9)



Inserting the sensor yourself


Ifyou'reinserting the Guardian™ 4sensor on your own, the followingtips can help you get the best performance and longest wear.

  1. Choose an insertion site on the back of your upper arm that’s free of scar tissue.
  2. Prep the skin using an alcohol wipe and let your arm completely dry before inserting.
  1. After insertion, remove the needle housing by gently holding the base of the sensoragainst the skin to prevent anymovement. Then, remove theneedle by holding the needlehousing and slowly pulling it straightout, away from the sensor.

    Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (10)

  1. Next, remove the adhesive linerfrom under the adhesive padandsecure the sensor in place.

    Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (11)


  1. Place the first piece of Oval Tape.

    Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (12)

  1. Connect the transmitter and removethe adhesive backing from the whiteadhesive tape to cover thetransmitter.

    Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (13)


  1. Place the second piece ofOval Tapein the opposite direction of the first.

    Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (14)

  1. Feel free toadd extra tape on top ofyourOval Tapeifyou'reactive, livein a humid area or just like alittleaddedsecurity.

    Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (15)


Want to see the full insertion process?

Watch this video for tips on inserting your sensor on the back of your arm.

Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (16)



Taping your sensor


Select the best sites

  • Insert your sensor and infusion sets in their approvedlocations. If you use the Guardian™ 4 sensor, wearingit in the back of the upper arm plays a big part inproviding the best possible experience.
  • Keep the site secure by selecting a spot that is flat,doesn’t have scar tissue, and won’t interfere withsummer clothing.

Secure your sites

  • Avoid using lotions, creams, or aerosols (likesunscreen), until after insertion and taping are done,as this may make it harder for the adhesive to stick.
  • Help the adhesive better stick to your skin bypreparing your site with alcohol.
  • After insertion, when removing the needle from thesensor or infusion set, hold the base of the sensor down with twofingers so that it stays in place.
  • Consider an additional piece of tape if you find thatyou’re sweating more, or summer clothing has yoursites more exposed. For your CGM, first apply the twopieces of Oval Tape as directed, and then add theadditional piece ofovertapeon top.​

Review this Tape tips and site management guide.

Go to Diabetes.shop for alternate tape options.

Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (17)



Pairing your Guardian 4 sensor andtransmitter to your MiniMed 780G insulinpump


Before you can start using your sensor, you must first pair your pump with your transmitter so they can begin communicating with each other when they are wirelessly connected.

You can pair only one transmitter with your pump. If you already have a transmitter paired with your pump, you must delete it before continuing.


To pair your pump and transmitter:

  1. Attach your transmitter to the charger and make sure the transmitter is fully charged. Keep your transmitter attached to the charger.

    Note: Both lights on the charger are off when the transmitter is fully charged. For more information, see the transmitter user guide.

    Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (18)

  2. From the Home screen, Press Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (19), then select Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (20).
  3. Place the transmitter (still attached to the charger) next to the pump.

    Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (21)

  4. Select Pair New Device and immediately remove the transmitter from the charger.

    Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (22)Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (23)

    The following events happen when the search process starts:

    • On the pump, the Searching…screen appears
    • On the transmitter, the light flashes 10 times and turns off

    The Select Device screen appears with a list of available devices.

  5. Select the CGM device that matches the serial number indicated on the back of the transmitter.

    Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (24)Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (25)

    If the correct serial number does not appear, select Search Again.

  6. If the connection is successful, a “Pairing successful!” message appears on the pump. When the transmitter is communicating with the pump, the sensor feature is turned on and Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (26),appears on the Home screen.

If your pump does not find your transmitter:

  1. Select OK on the Device not found alert. The Select Device screen appears.
  2. Confirm that the device is not already paired with a pump.
  3. Confirm that the device is ready to pair with the pump.
  4. Make sure the pump is away from any electronic devices that might cause interference, such as cellular phones and other wireless devices that are not paired with the MiniMed 780G system and other wireless devices.
  5. Move the device closer to the pump.
  6. Try to pair the pump with the device again.


Starting your sensor


After the sensor is inserted and paired with the transmitter, the pump will display a Start New Sensor screen.

To start a new sensor:


  1. Select Start New Sensor when it appears on the pump screen.

    Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (27)

  2. The “Sensor warm up X:XX hr” message appears.
    Note: It may take up to five minutes for the “Sensor warm up X:XX hr” message to appear. The warm up period lasts two hours.
  3. Select OK.
    The “Sensor warm up...” message appears on the Home screen until the sensor warm up is complete. After the warm up is complete, the pump begins receiving SG readings.

    Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (28)



Sensor updating alert


What does it mean?

The Guardian™ 4 sensor constantlymonitors the health of the sensor to ensureit'sreliable for use. Now that the system isfree of calibrations, additional safety checkshave been put into place. As a result, theSensor updating alert may occur when thesystem is confirming the reliability of thesensor.​


What action should you take if Sensor updating occurs?

Most sensors resume normal function within 1 hour, so there is no need to take action unless recommended by the system.


Have you had the alert for more than 3 hours?

In the event that the updating lasts for more than 3 hours, the recommendation is to replace the sensor to maximize time in SmartGuard™ technology.* The alert will only repeat if the estimated timegiven was incorrect.

Check out this video that goes over the Sensor updating alert in more detail.

Order a replacement sensor.


* Monitor blood glucose (BG) with a meter for treatment decisions during this time.

Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (29)



Unpairing a transmitter from your pump


Only one transmitter can be connected (or paired) to the pump at one time. In order to connect a new transmitter, you will need to unpair the current transmitter.​

  1. From the Home screen, Press Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (30), then select Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (31). The Paired Devices screen appears.

    Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (32)

  2. Select CGM with the correct serial number. The Device Info screen appears.

    Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (33)

  3. Select Unpair. The Unpair Device? screen appears.

    Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (34)

  4. Select Yes to confirm or select No to cancel.
    When the transmitter is unpaired from the pump, a No Paired CGM banner appears on the Home screen.



Disconnecting the transmitter and removing your sensor


When your sensor life is depleted you will need to remove your sensor to insert a new one.​

  1. Carefully remove the tape and any additional adhesive from the transmitter.
  2. Remove the adhesive tab from the top of the transmitter.
  3. Hold the transmitter with one hand and pinch the flexible side arms of the sensor with the thumb and forefinger of your other hand.
  4. Gently pull the transmitter away from the sensor.
  5. Pull the sensor away from your body to remove it.
  6. Dispose of the sensor properly, in a sharps container.
  7. Place the transmitter on the charger.

MiniMed™ 780G system supportSensor supportSensor and transmitter FAQsUser guides and manuals

Guardian™ 4 Sensor - Sensor and Transmitter Support | Medtronic (2024)
Top Articles
Latest Posts
Article information

Author: Delena Feil

Last Updated:

Views: 6129

Rating: 4.4 / 5 (45 voted)

Reviews: 84% of readers found this page helpful

Author information

Name: Delena Feil

Birthday: 1998-08-29

Address: 747 Lubowitz Run, Sidmouth, HI 90646-5543

Phone: +99513241752844

Job: Design Supervisor

Hobby: Digital arts, Lacemaking, Air sports, Running, Scouting, Shooting, Puzzles

Introduction: My name is Delena Feil, I am a clean, splendid, calm, fancy, jolly, bright, faithful person who loves writing and wants to share my knowledge and understanding with you.